Hikvision How to Configure Indoor Station Alarm Output

How to Configure Indoor Station Alarm Output

There are two ways to trigger alarm output of indoor station:
1. Zone alarm :when zone alarm is detected, it will trigger alarm output of indoor station
2. Calling linkage: when door station or other indoor station calls indoor station, it will trigger alarm output

1. Second generation indoor station( take DS-KH8520-WTE1 for example in this document)
2. iVMS-4200 V3.5.0.7 or later

 

1. Zone alarm

1) Go to Remote Configuration-Intercom-Zone alarm, choose Area No. you pay attention to, set alarm type and other parameters

2) Choose the relay you want to trigger when zone alarm is detected and save

2. Calling linkage

1) Go to Remote configuration-Intercom-Calling Linkage, enable this function and choose the relay you want to be triggered when indoor station receive call

3. Configure relay settings

1) Go to Remote configuration-Intercom-Relay, choose the relay, edit name and active time of this alarm output. Output Delay is active time after alarm output is triggered

IF THIS WAS HELPFUL, PLEASE DON’T FORGET TO RATE OUR SERVICE BELOW

Leave a Reply